Plants growing inside a Saveer plant growth chamber

Controlled environments.
Built for plant research.

Chambers designed to provide stable, programmable environments for plant growth, breeding and experimental research.

Control

Precise control of temperature, humidity, light and CO₂ creates defined, repeatable conditions for plant experiments.

Program

Set multiple environmental conditions and schedule up to 15 real-time programmes through the microprocessor-based HMI controller.

Monitor

Track conditions in real time with data logging, alarm history, graph and Excel export, USB output and remote monitoring.

Repeat

Stable temperature, controlled humidity and uniform airflow help create consistent conditions for repeatable experiments.

Four chambers. Different scales.
One controlled environment.

From compact reach-in chambers for focused experiments to a walk-in chamber for larger-scale studies, the FGR range provides controlled growing environments for different research requirements.

Plants growing inside the FGR-500FGR-500 Reach-In plant growth chamber
FGR-500
Reach-In Chamber
500 L0.45 m² growth area
Plants growing inside the FGR-1000FGR-1000 Reach-In plant growth chamber
FGR-1000
Reach-In Chamber
1,000 L0.78 m² growth area
Plants growing inside the FGR-2000FGR-2000 Reach-In plant growth chamber
FGR-2000
Reach-In Chamber
2,300 L1.44 m² growth area
Plants growing inside the FGW-10KFGW-10K Walk-In plant growth chamber
FGW-10K
Walk-In Chamber
10,000 L4.43 m² growth area

From reach-in to walk-in, built around your research.

Exterior, doors, growing area, LED canopy and control, step through the range, from the compact FGR-500 to the FGW-10K Walk-In Chamber.

Plants growing inside the FGR-500FGR-500 Reach-In plant growth chamber

FGR-500 Reach-In Chamber.

The compact reach-in for focused experiments. 500 litres and 0.45 m² of growth area under PAR-optimised LED, with ±0.5°C control and a 4-inch HMI, sized to move where the science needs it.

Plants growing inside the FGR-1000FGR-1000 Reach-In plant growth chamber

FGR-1000 Reach-In Chamber.

Twice the volume for growing programmes. 1,000 litres, 0.78 m² of growth area and up to 600 µmol/m²/s of tunable light, with the same precision control and data logging across every shelf.

Plants growing inside the FGR-2000FGR-2000 Reach-In plant growth chamber

FGR-2000 Reach-In Chamber.

The flagship reach-in. A 2,300-litre interior with 1.44 m² of growth area, up to 1000 µmol/m²/s across four LED bands and 1.6 m of usable height for taller specimens, the model this page is built around.

Plants growing inside the FGW-10KFGW-10K Walk-In plant growth chamber

FGW-10K Walk-In Chamber.

Step inside. A 10,000-litre walk-in with 4.43 m² of growth area and 2.0 m of height for large-scale studies, driven by a larger 7/10-inch HMI, the same controlled environment, at facility scale.

FGR-500|FGR-1000|FGR-2000|FGW-10K

One chamber.
Every system, mapped.

Explore the key components that work together to create a stable, programmable environment for plant research.

1

HMI Touchscreen

Microprocessor-based touchscreen control for temperature, humidity, light and CO₂ programming.

2

LED Canopy

PAR-optimised LED lighting with configurable white, red, blue and far-red wavelengths.

3

Reach-In Doors

Insulated doors provide convenient access to the controlled growth environment.

4

Adjustable Racks

Flexible rack positioning lets the growth space accommodate different plant sizes and setups.

12345678
Dimensions & Capacity
External dimensions3075 × 995 × 2500mm
Internal capacity2300litres
Growth height1600mm
Environment
Temperature range10 - 45°C light off
Temperature precision±0.5°C
RH% range (light on)50 - 90%
Lighting
SpectrumWhite · Red · Blue · Far-Red
Light intensity0 - 1000μmol/m²/s
Electrical
Power supply220 V AC · single-phase
Optional Add-ons
  • Customized temperature range
  • Application-specific light bands
  • Special high-intensity lighting
  • Gas control: CO₂ / O₂ / custom
  • Any further feature on request
Light intensity measured 15 cm from the source · Customizations available on request
5

Cooling System

CFC-free cooling with hot-air bypass and condensing-unit technology.

6

Airflow System

Uniform, parallel air distribution helps maintain consistent conditions throughout the chamber.

7

Fresh Air Control

Fresh-air supply can be controlled through the HMI according to the experimental requirement.

8

Data & Alarm Monitoring

Alarm history, data logging, USB export and remote monitoring support continuous tracking.

Controlled conditions, built around your research.

Every Plant Growth Chamber brings together environmental control, lighting, airflow and monitoring systems to create stable, programmable conditions for plant research.

Precision environment control
Precision Environment Control
Temperature & Humidity
  • Temperature control up to ±0.5°C
  • Operating range of +10°C to +45°C*
  • 50-90% RH range
Programmable LED lighting
Programmable Lighting
Plant-Optimised Illumination
  • PAR-optimised LED lighting
  • White, red, blue and far-red options
  • Flexible canopy configuration
  • Optional dimming
Airflow and cooling
Airflow & Cooling
Stable Conditions Throughout
  • Uniform parallel air distribution
  • CFC-free cooling system
  • Hot-air bypass with condensing unit
  • Controllable fresh-air supply
Control and monitoring
Control & Monitoring
Everything Under Control
  • HMI touchscreen control
  • Temperature, RH, light & CO₂ programming
  • Up to 15 real-time programmes
  • Data logging, alarms and remote monitoring

Every variable.
Under your control.

System 01 · Cooling

Cooling that keeps conditions stable.

CFC-free cooling, hot-air bypass and condensing-unit technology work together to maintain the required chamber temperature.

01Cooling
System 02 · Airflow

Air moves where plants need it.

Parallel air distribution maintains a consistent environment across the growth space while minimising disturbance to plants. Airflow direction can also be configured according to the application.

02Airflow
System 03 · Illumination

A spectrum designed for plant growth.

PAR-optimised LED lighting configurable with white, red, blue and far-red wavelengths, flexible canopy arrangements and optional dimming. Maximum light intensity varies by model (500 / 600 / 1000 µmol/m²/s).

03Illumination
System 04 · Control
Chamber · 01 Live
Temp
19.8°
RH
63%

Control. Log. Monitor remotely.

Programme temperature, humidity, light and CO₂ from the HMI touchscreen. Monitor conditions in real time, review alarm history and export experimental data through graph, Excel or USB formats.

04Control

Tell us what your research needs. We’ll help define the environment.

Share your crop, experimental requirements, environmental parameters and scale, and our team will help you identify the right chamber configuration.

Let’s Connect
01

Share your requirements

Tell us about your crop, experiment and conditions.

02

Technical consultation

Discuss temperature, humidity, lighting and control requirements.

03

Define the configuration

Select the appropriate chamber size and features.

04

Get started

Move from requirements to a research-ready environment.

Start a conversation

Fields marked * are required.

One platform. Four chamber formats for different research needs.

From compact FGR-500 units to the large FGW-10K Walk-In Chamber, Saveer's Plant Growth Chamber range is designed to support different scales of plant research and cultivation. Choose the chamber size that fits your available space, plant height, growth area and experimental requirements. Across the range, precise temperature and humidity control, PAR-optimised lighting and programmable monitoring help create repeatable growing conditions.

The models share a common temperature range of +10 to 45°C (lights off) and +12 to 45°C (lights on), with ±0.5°C control and a 50-90% RH range. The reach-in models use a 4-inch HMI panel, while the FGW-10K Walk-In Chamber uses a larger 7/10-inch HMI option.

ParametersFGR-500Reach-In ChamberFGR-1000Reach-In ChamberFGR-2000Reach-In ChamberFGW-10KWalk-In Chamber
External DimensionW × D × H852×876×1974 mm2.7×2.8×6.4 ft1006×1194×2078 mm3.3×3.9×6.8 ft3075×955×2216 mm10.0×3.1×7.2 ft3280×1820×2500 mm10.7×5.9×8.2 ft
Internal DimensionW × D × H750×600×1195 mm2.4×1.9×3.9 ft900×870×1330 mm2.9×2.8×4.3 ft1800×800×1600 mm5.9×2.6×5.2 ft2670×1660×2300 mm8.7×5.4×7.5 ft
Capacity500 L1,000 L2,300 L10,000 L
HMI Panel4 inch4 inch4 inch7 / 10 inch
Growth Area0.45 m²4.84 ft²0.78 m²8.42 ft²1.44 m²15.50 ft²4.43 m²47.57 ft²
Growth Height1.1 m3.5 ft1.3 m4 ft1.6 m5.2 ft2 m6.5 ft
Temperature Range+10 to 45°C (off)+12 to 45°C (on)+10 to 45°C (off)+12 to 45°C (on)+10 to 45°C (off)+12 to 45°C (on)+10 to 45°C (off)+12 to 45°C (on)
Temperature Control±0.5°C±0.5°C±0.5°C±0.5°C
RH% Rangelight on50-90%50-90%50-90%50-90%
Adjustable Light GridNoOptionalYesYes
Light Intensityat 15 cm from source0-500 µmol/m²/s0-600 µmol/m²/s0-1000 µmol/m²/s0-1000 µmol/m²/s
Electricity Requirement220-230 V AC50 Hz · 1-phase220-230 V AC50 Hz · 1-phase220-230 V AC50 Hz · 1-phase415-440 V AC3-phase

*Adjustable racks available for changing height. Light intensity measured at 15 cm from the light source. Specifications may vary by configuration.

Let's worktogether!

↓ Continue to scroll ↓