Control
Precise control of temperature, humidity, light and CO₂ creates defined, repeatable conditions for plant experiments.
Precise control of temperature, humidity, light and CO₂ creates defined, repeatable conditions for plant experiments.
Set multiple environmental conditions and schedule up to 15 real-time programmes through the microprocessor-based HMI controller.
Track conditions in real time with data logging, alarm history, graph and Excel export, USB output and remote monitoring.
Stable temperature, controlled humidity and uniform airflow help create consistent conditions for repeatable experiments.
From compact reach-in chambers for focused experiments to a walk-in chamber for larger-scale studies, the FGR range provides controlled growing environments for different research requirements.








Exterior, doors, growing area, LED canopy and control, step through the range, from the compact FGR-500 to the FGW-10K Walk-In Chamber.


The compact reach-in for focused experiments. 500 litres and 0.45 m² of growth area under PAR-optimised LED, with ±0.5°C control and a 4-inch HMI, sized to move where the science needs it.


Twice the volume for growing programmes. 1,000 litres, 0.78 m² of growth area and up to 600 µmol/m²/s of tunable light, with the same precision control and data logging across every shelf.


The flagship reach-in. A 2,300-litre interior with 1.44 m² of growth area, up to 1000 µmol/m²/s across four LED bands and 1.6 m of usable height for taller specimens, the model this page is built around.


Step inside. A 10,000-litre walk-in with 4.43 m² of growth area and 2.0 m of height for large-scale studies, driven by a larger 7/10-inch HMI, the same controlled environment, at facility scale.
Explore the key components that work together to create a stable, programmable environment for plant research.
Microprocessor-based touchscreen control for temperature, humidity, light and CO₂ programming.
PAR-optimised LED lighting with configurable white, red, blue and far-red wavelengths.
Insulated doors provide convenient access to the controlled growth environment.
Flexible rack positioning lets the growth space accommodate different plant sizes and setups.
CFC-free cooling with hot-air bypass and condensing-unit technology.
Uniform, parallel air distribution helps maintain consistent conditions throughout the chamber.
Fresh-air supply can be controlled through the HMI according to the experimental requirement.
Alarm history, data logging, USB export and remote monitoring support continuous tracking.
Every Plant Growth Chamber brings together environmental control, lighting, airflow and monitoring systems to create stable, programmable conditions for plant research.




CFC-free cooling, hot-air bypass and condensing-unit technology work together to maintain the required chamber temperature.
Parallel air distribution maintains a consistent environment across the growth space while minimising disturbance to plants. Airflow direction can also be configured according to the application.
PAR-optimised LED lighting configurable with white, red, blue and far-red wavelengths, flexible canopy arrangements and optional dimming. Maximum light intensity varies by model (500 / 600 / 1000 µmol/m²/s).
Programme temperature, humidity, light and CO₂ from the HMI touchscreen. Monitor conditions in real time, review alarm history and export experimental data through graph, Excel or USB formats.
Share your crop, experimental requirements, environmental parameters and scale, and our team will help you identify the right chamber configuration.
Let’s ConnectTell us about your crop, experiment and conditions.
Discuss temperature, humidity, lighting and control requirements.
Select the appropriate chamber size and features.
Move from requirements to a research-ready environment.
Fields marked * are required.
From compact FGR-500 units to the large FGW-10K Walk-In Chamber, Saveer's Plant Growth Chamber range is designed to support different scales of plant research and cultivation. Choose the chamber size that fits your available space, plant height, growth area and experimental requirements. Across the range, precise temperature and humidity control, PAR-optimised lighting and programmable monitoring help create repeatable growing conditions.
The models share a common temperature range of +10 to 45°C (lights off) and +12 to 45°C (lights on), with ±0.5°C control and a 50-90% RH range. The reach-in models use a 4-inch HMI panel, while the FGW-10K Walk-In Chamber uses a larger 7/10-inch HMI option.
| Parameters | FGR-500Reach-In Chamber | FGR-1000Reach-In Chamber | FGR-2000Reach-In Chamber | FGW-10KWalk-In Chamber |
|---|---|---|---|---|
| External DimensionW × D × H | 852×876×1974 mm2.7×2.8×6.4 ft | 1006×1194×2078 mm3.3×3.9×6.8 ft | 3075×955×2216 mm10.0×3.1×7.2 ft | 3280×1820×2500 mm10.7×5.9×8.2 ft |
| Internal DimensionW × D × H | 750×600×1195 mm2.4×1.9×3.9 ft | 900×870×1330 mm2.9×2.8×4.3 ft | 1800×800×1600 mm5.9×2.6×5.2 ft | 2670×1660×2300 mm8.7×5.4×7.5 ft |
| Capacity | 500 L | 1,000 L | 2,300 L | 10,000 L |
| HMI Panel | 4 inch | 4 inch | 4 inch | 7 / 10 inch |
| Growth Area | 0.45 m²4.84 ft² | 0.78 m²8.42 ft² | 1.44 m²15.50 ft² | 4.43 m²47.57 ft² |
| Growth Height | 1.1 m3.5 ft | 1.3 m4 ft | 1.6 m5.2 ft | 2 m6.5 ft |
| Temperature Range | +10 to 45°C (off)+12 to 45°C (on) | +10 to 45°C (off)+12 to 45°C (on) | +10 to 45°C (off)+12 to 45°C (on) | +10 to 45°C (off)+12 to 45°C (on) |
| Temperature Control | ±0.5°C | ±0.5°C | ±0.5°C | ±0.5°C |
| RH% Rangelight on | 50-90% | 50-90% | 50-90% | 50-90% |
| Adjustable Light Grid | No | Optional | Yes | Yes |
| Light Intensityat 15 cm from source | 0-500 µmol/m²/s | 0-600 µmol/m²/s | 0-1000 µmol/m²/s | 0-1000 µmol/m²/s |
| Electricity Requirement | 220-230 V AC50 Hz · 1-phase | 220-230 V AC50 Hz · 1-phase | 220-230 V AC50 Hz · 1-phase | 415-440 V AC3-phase |
*Adjustable racks available for changing height. Light intensity measured at 15 cm from the light source. Specifications may vary by configuration.